HMS-300/350/400/450/500-1T
Com potência de saída de até 500 VA, a nova linha de microinversores HMS-500-1T Hoymiles está entre as mais bem classificadas para microinversores 1 em 1.
Cada microinversor conecta até 1 módulo fotovoltaico com MPPT e monitoramento independentes, garantindo maior coleta deenergia e mais facilidade na manutenção.
A nova solução Sub-1G sem fio possibilita uma comunicação maisestável sob várias condições ambientais.
Hoymiles’s new photovoltaic microinverter HMS-500-1T series is connected to one panel and is flexible for various applications.
All of the Hoymiles HMS-500-1T series are equipped with reactive power control and can meet the requirements of EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, etc.
HMS-500-1T series with the new Sub-1G wireless solution enables more stable communication under various environmental conditions.
Dimensions:182 × 164 × 30mm | Max. input voltage: 60V |
Rated output power: 300VA | Number of modules connected: 1 |
Commonly used module power: 240W to 405W+ | MPPT voltage range: 16V–60V |
Max. input current: 11.5A | Number of MPPTs: 1 |
Max. input short circuit current (A): 16A |
Dimensions:182 × 164 × 30mm | Max. input voltage: 60V |
Rated output power: 350VA | Number of modules connected: 1 |
Commonly used module powe280W to 470W+ | MPPT voltage range: 16V–60V |
Max. input current: 11.5A | Number of MPPTs: 1 |
Max. input short circuit current (A): 16A |
Dimensions:182 × 164 × 30mm | Max. input voltage: 65V |
Rated output power: 400VA | Number of modules connected: 1 |
Commonly used module power: 320W to 540W+ | MPPT voltage range: 16V–60V |
Max. input current: 12.5A | Number of MPPTs: 1 |
Max. input short circuit current (A): 20A |
Dimensions:182 × 164 × 30mm | Max. input voltage: 65V |
Rated output power: 450VA | Number of modules connected: 1 |
Commonly used module power: 360W to 600W+ | MPPT voltage range: 16V–60V |
Max. input current: 13.3A | Number of MPPTs: 1 |
Max. input short circuit current (A): 20A |
Dimensions:182 × 164 × 30mm | Max. input voltage: 65V |
Rated output power: 500VA | Number of modules connected: 1 |
Commonly used module power: 400W to 670W+ | MPPT voltage range: 16V–60V |
Max. input current: 14A | Number of MPPTs: 1 |
Max. input short circuit current (A): 20A |
● With Reactive Power Control, compliant with EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, etc.
● Safer for rooftop solar stations with rapid shutdown compliance and isolated transformer
● Connected to one panel, flexible for various applications
● Sub-1G wireless solution allows stable communication with Hoymiles gateway DTU
● AC Trunk Connector
● AC Trunk Port Cap
● AC Trunk End Cap
● 25 Years Extendable
● VDE-AR-N 4105: 2018
● VFR2019
● IEC/EN 62109-1/-2
● IEC/EN 61000-6-1/-2/-3/-4
● IEC/EN 61000-3-2/-3
DTU-Lite-S, DTU-Pro-S, DTU-Wlite-S
The Hoymiles HMS-500-1T series is meticulously engineered to deliver exceptional stability and performance. Besides the HMS-500-1T series, Hoymiles has more excellent products to explore!