The HAT-HV-EUG1 Series is designed for retrofitting PV systems, including power classes ranging from 5 kW to 10 kW. It can be installed with existing PV inverters, forming an AC coupling system.
The intelligent EMS function supports self-consumption mode, economic mode, and backup mode for multi-scenario applications.
Moreover, the remote monitoring management through S-Miles Cloud allows users to track the full status of the system operation over time, maximizing power and energy utilization.
The HAT-HV-EUG1 Series is designed for retrofitting PV systems, including power classes ranging from 5 kW to 10 kW. It can be installed with existing PV inverters, forming an AC coupling system.
The intelligent EMS function supports self-consumption mode, economic mode, and backup mode for multi-scenario applications.
Moreover, the remote monitoring management through S-Miles Cloud allows users to track the full status of the system operation over time, maximizing power and energy utilization.
Dimensions: 502 × 486 × 202mm | Max. output apparent power (on-grid): 5,000VA |
Weight: 23kg | Max. input power (on-grid): 10,000W |
Voltage range: 170V–600V | Max. efficiency: 97.5% |
Max. charge/discharge current: 20A/20A | Protection degree: IP65 |
Dimensions: 502 × 486 × 202mm | Max. output apparent power (on-grid): 6,000VA |
Weight: 23kg | Max. input power (on-grid): 12,000W |
Voltage range: 170V–600V | Max. efficiency: 97.5% |
Max. charge/discharge current: 20A/20A | Protection degree: IP65 |
Dimensions: 502 × 486 × 202mm | Max. output apparent power (on-grid): 8,000VA |
Weight: 23kg | Max. input power (on-grid): 16,000W |
Voltage range: 170V–600V | Max. efficiency: 97.5% |
Max. charge/discharge current: 30A/30A | Protection degree: IP65 |
Dimensions: 502 × 486 × 202mm | Max. output apparent power (on-grid): 10,000VA |
Weight: 23kg | Max. input power (on-grid): 16,000W |
Voltage range: 170V–600V | Max. efficiency: 97.5% |
Max. charge/discharge current: 30A/30A | Protection degree: IP65 |
● Intelligent export limitation and 100% three-phase imbalanced output
● Compatible with multiple batteries, providing users with more choices
● UPS level switching time <10 ms
● Ultralight for easy installation and space-saving
● Built-in dry contact flexibly monitors earth fault alarm and provides load control or generator control
● Max. 10 parallel inverters
● 5 Years(Global)
● 10 Years (Europe, Australia & New Zealand, the United States)
● EN 50549
● VDE-AR-N 4105
● AS/NZS 4777.2
● IEC 62109-1
● IEC 62109-2
● IEC 62477-1
● EN 61000-6-1
● EN 61000-6-3